Sika s experience would be to avoid cold roof design where possible.
Sarnafil cold roof ventilation.
In a cold roof.
Cold roofs are generally considered as difficult to design and construct and future upgrading of insulation requires invasive destructive means which should be kept in mind.
There must be an adequate void minimum 50mm between the deck and the insulation traditionally mineral wool to allow free movement of air and to prevent moisture vapour being transmitted from the building outwards where.
Cold roofs by the way are not recommended for high humidity areas see the blog on how to insulate roofs of swimming pools saunas and high humidity areas.
This should ideally be in the form of soffit vents to the underside of the fascia boards but as many flat roofs were built without soffits it is often in the form of unsightly mushroom vents on top of the roof or soffit vents incorrectly fitted in to the fascia boards.
Some of britain s best known buildings feature sika sarnafil roofs and it is the system of choice for applications in education commerce retail leisure travel and many other sectors.
Roof spaces must have ventilation openings on two opposite sides.
The design of cold roofs usually occurs when external abutment height provision is problematic thus making a warm roof not achievable.
Ventilation for cold roofs.
An open cross ventilation space is required above the insulation to prevent condensation occurring in the insulation layer and compromising the integrity of the roof.
Since the 1960 s the performance and longevity of sika sarnafil roofs has been demonstrated in.
2011 code of practice for control of condensation in buildings stipulates that there should be a.
Insulation is laid below the roof deck typically between the rafters.
Berkshire uses sika sarnafil s single ply membrane system on its roofs terraces and balconies.
Without ventilation there is a risk that condensation will form on the underside of the roof deck.
You only need ventilation in a cold roof.
Sika sarnafil is the leading manufacturer of single ply roofing membranes for flat roof waterproofing.
In a cold roof construction the sarnafil membrane is installed directly to the structural decking usually timber with firrings to fall.
Sarnafil cold roof ventilation in a cold roof construction the sarnafil membrane is installed directly to the structural decking usually timber with firrings to fall.
2018 recommends warm deck roofing designs wherever vertical space permits.
Cold roofs have the principal insulation below the structural deck and are recommended only for small or domestic roof areas where it is possible to provide cross ventilation above the insulation.
Without ventilation there is a risk of condensation forming on the underside of the roof deck.